Login:   Password:
Not Register?    Sign Up NOW!
Date: 21 November 2009
Google
 
Wearable blood pressure sensor offers 24/7 continuous monitoring :Device could help diagnose hypertension, heart disease  
Topic Name: Wearable blood pressure sensor offers 24/7 continuous monitoring :Device could help diagnose hypertension, heart disease
SocialTwist Tell-a-Friend

Category: Bioelectronics

Research persons: H. Harry Asada

Location: Cambridge, United States

Details

Wearable blood pressure sensor offers 24/7 continuous monitoring :Device could help diagnose hypertension, heart disease

High blood pressure is a common risk factor for heart attacks, strokes and aneurysms, so diagnosing and monitoring it are critically important. However, getting reliable blood pressure readings is not always easy.

Visits to the doctor's office can provoke anxiety that distorts blood pressure readings, and even when accurate, such visits provide only one-time snapshots of the patient's condition. To overcome these obstacles, MIT engineers have built a wearable blood pressure sensor that can provide continuous, 24-hour monitoring.

Blood pressure can change from minute to minute, so continuous monitoring offers a much broader picture of cardiovascular health. The new monitor, which loops around the wrist and the index finger, is just as accurate as traditional cuff devices but much less cumbersome, allowing it to be worn for hours or days at a time.

"The human body is so complex, but the cuff gives only snapshot data," says Harry Asada, an MIT mechanical engineer who led the development of the new monitor. "If you get signals all of the time you can see the trends and capture the physical condition quite well."

Such devices could be used to keep tabs on hypertension as well as sleep apnea, which causes sufferers to stop breathing many times throughout the night. Eventually, doctors may be able to use data gathered from continuous monitoring to predict when a heart attack may occur, says Asada, the Ford Professor of Engineering and director of MIT's d'Arbeloff Laboratory for Information Systems and Technology.

CardioSign, a company launched by Asada's former student, is working on commercializing the device and hopes to start clinical trials soon. Asada said he believes a commercial version of the device could be available within five years, once it becomes easier to use, more reliable and cheaper to manufacture.

The latest prototype was developed jointly with industrial sponsor Sharp Corporation, and Dr. Andrew Reisner of Massachusetts General Hospital took the lead in clinical applications and human subject tests.

No cuff required:

Traditional blood pressure monitoring requires a cuff, wrapped around the upper arm and inflated until blood flow is completely cut off. The examiner then gradually releases the pressure, listening to the flow until the pulse can be detected.

With the new monitor, no cuff is required. Instead, the device takes advantage of a method called pulse wave velocity, which allows blood pressure to be calculated by measuring the pulse at two points along an artery.

In early models, the researchers used the heart as one of the points, with a heart monitor measuring the EKG. However, EKGs aren't always accurate, and a heart monitor can be uncomfortable, so the researchers decided to use two points on the hand instead.

That posed a challenge because blood pressure in the hand varies depending on its position: If the arm is raised above the heart, the pressure will be higher than if it is below the heart. The researchers solved that dilemma by incorporating a sensor that measures acceleration in three dimensions, allowing the hand position to be calculated at any time.

This not only compensates for the error due to height changes, but also allows them to calibrate the sensor for more accurate calculation of blood pressure. As the wearer raises the hand up and down, the hydrostatic pressure changes at the sensor. Correlating the change of pulse wave velocity to the hydrostatic pressure change, the system can automatically calibrate its measurement.

Once the blood pressure information is gathered, the data can be transmitted via radio signals or wireless Internet. The device runs on a tiny battery, about the same size as the ones that power watches.

The wearable blood pressure sensor was born from a collaboration called the Home Automation and Healthcare Consortium, which launched in 1995 and included several MIT faculty members and about 20 companies.

The team's first project was a ring that measures pulse rate and the amount of oxygen present in the blood. After developing the ring, Asada decided to move on to blood pressure sensing, which offers even more valuable information about a patient's health.

The project was funded by the National Institutes of Health, National Science Foundation and the Sharp Corporation.

 

About the researcher :

H. Harry Asada

Ford Professor of Engineering
Director, d'Arbeloff Laboratory for Information Systems and Technology
Head, Control, Instrumentation, and Robotics

Research Interests:

Robotics, Biomedical Engineering, Dynamic Systems and Control, Information Technology, Design, and Manufacturing

Teaching Interests:

Dynamic Systems and Control; Robotics; Intelligent Control

Educational Background:

S.B. Mechanical Engineering, Kyoto University, 1973
S.M. Precision Engineering, Kyoto University, 1975
Ph.D. Precision Engineering, Kyoto University, 1979

Scientific and Professional Societies:

ASME; IEEE

Honors and Awards:


1. Best Paper Award, Society of Instrument and Control Engineers, August 1979
2. Best Paper Award, Society of Instrument and Control Engineers, August 1984
3. SME Outstanding Young Manufacturing Engineer Award, September 1984
4. O. Hugo Schuck Best Paper Award, American Control Council, June 1985
5. Y. Sawaragi Best Paper Award, Japanese Associate of Automatic Control Engineers, May 1988
6. Best Paper Award, Society of Instrument and Control Engineers, July 1990
7. Best Paper Award, 1993 IEEE International Conference on Robotics and Automation, June 1993
8. Best Paper Award, 1995 ASME Heat Pump Symposium, November 1995
9. Ford Professor of Engineering, School of Engineering, MIT, September 1996
10. Kayamori Best Paper Award, Automation Theory and Application, 1997 IEEE International Conference on Robotics and Automation, April 1997
11. Dynamic Systems and Control Outstanding Researcher Award, ASME, November 1998
12. Best Paper Award, 1999 IEEE International Conference on Robotics and Automation, May 1999
13. ASME Fellow, Dynamic Systems and Control Division, September 2001
14. Best Journal Paper Award, Advanced Robotics, October 2002

 

Professional Development Activities :


Stochastic recruitment and broadcast feedback, May 2005-Present, Principal Investigator
Vast DOF robotic systems, Oct.2002-Present, Principal Investigator
Wearable blood pressure sensors, Sept.2002-Present, Principal Investigator
Fingernail Sensors, Oct.1998-June 2005, Principal Investigator
Wearable Health Monitoring Systems, Oct.1997-Present, Principal Investigator
Intelligent Control of Building Energy Systems, Jan.1989 - Feb. 2005, Principal Investigator
Home Automation and Healthcare, Oct.1995 - Sept.2002, Principal Investigator
PC-Based NC Control, Oct. 1995 - Sept. 1998, Principal Investigator
Co-Simulation of Dynamical Systems, April 1997-Sept.2001, Principal Investigator
Leaders for Manufacturing Program: June 1989 - June 1993
Robotic Assembly: Sept. 1985 - March 1993, Principal Investigator
Design and Control of Direct-Drive Robots: Sept. 1980 - Aug. 1985, Principal investigator

The sponsors of these projects include National Science Foundation, National Institute of Health, Office of Naval Research, US Army, CIMIT, Boeing Corporation, Sharp, Mitsubishi Heavy Industries, Marquette Medical Equipment, Hill-Rom, Gillette/Braun, Matsushita Electric Industrial, Matsushita Electric Works, Shin-Nippon Koki, Daikin, Denso, Toshiba, Samsung, Daewoo Heavy Industries, MPM, NIRO, Shimadzu, Toyota Motor, Ford Motor, GM, Kolon Glotech, Motorola, and Delco Electronics.

 

Contact Information of researcher:

Room 3-348
Massachusetts Institute of Technology
77 Massachusetts Avenue
Cambridge MA 02139-4307
Phone: 617-253-6257  
Email:


Tags: wearable blood pressure sensor - no cuff -
Research Documents:
Related research: A molecule that paves the way for seizures, Brain Images Reveal the Secret to Higher IQ, Develop a quick, simple and cheap immune-system test, Georgia Tech’s Researchers have developed a novel fabrication method of copper connections for high-speed computing, Lab-on-a-chip at home: Make Your Own Microfluidic Testing Device With New Kit, Molecular forklifts overcome obstacle to 'smart dust', Nano Precision Pump: an implantable drug-delivery device for treating hepatitis C and other chronic illnesses, Researchers developed a new process that lead to a significant reduction in heat generated by silicon chips or microprocessors, Researchers Discovered Fundamental State of Matter will Helpful to Transform Materials Research, Electronics Design, Sensors to locate passengers releasing pathogens inside airline cabins.

Add Research

Full Name *
Email address *
Location
Your Research *

 
Home | Members.Benefit | Privacy.Policy | Bookmark.This.Page | Contact.Us
© 2006 - 2007 4engr. All Rights reserved

|Conveyor technology