| TRITIUM ON SURFACE |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field ( Surface contamination measurements)
Radiation detected : Low energy beta radiation from tritium, C-14, or from Tc-99
Operation
This system is a passive integrating detector... more |
| TRITIUM IN AIR |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurements)
Radiation detected : Airborne tritium
Operation
This system is a passive integrating detector for field measurement of airborne tritium. It consists... more |
| TRITIUM CONTAMINATION IN PIPES TOOLS and OBJECTS |
Radio System |
|
|
System: Ion Transfer Electret Ion Chamber
Lab/Field: Field (In situ measurement )
Radiation detected : Low energy beta emitters such as tritium inside pipes, on contaminated tools and other irregularly shaped objects.
Introduction
... more |
| Radon in Water |
Radio System |
|
|
Significance
Subsoil radon is in intimate contact with the well water and carries some dissolved radon. When water is used in homes for shower, in laundry or other purposes, radon gets released from water and spreads into room air. EPA estimates... more |
| Radon Flux from Mill Tailings, Phosphate Stacks & Ground |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurement )
Radiation detected : Radon flux from ground, phosphate stacks, uranium mill tailings
Introduction
The passive measurement of radon flux from the... more |
| Plutonium and Uranium in Soil |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurement on soils)
Radiation detected: Alpha
Operation
This system is a passive integrating detector for measurement of alpha-emitting contaminants in soils... more |
| LOW ENERGY XRAYS mammography air scatter skyshine video terminal |
Radio System |
|
|
System: Ultra low energy thin window (7 mg cm2 ) X ray measuring Electret Ion Chamber for measuring mammography X rays, medical X rays, Sky shine or air scatter X rays and video terminal emitted X rays
Lab/Field: Field (In situ measurement )
... more |
| ENVIRONMENTAL AND WORK PLACE GAMMA RADIATION |
Radio System |
|
|
System: Electret Ion Chamber
Lab/Field: Field (In situ measurements)
Radiation detected: Gamma Radiation
Operation
This system is a passive integrating detector system for field measurement of X or gamma radiation... more |
| Custome Electret material made from FEP Teflon |
Radio System |
|
|
Custom Prepared To meet your requirement at economical price
Uses:
For air cleaning in small inaccessible places such as CD players PC hard disks etc.,
For miniature microphones, electret speakers,
For radon and radiation detectors
... more |
| ALPHA SURFACE CONTAMINATION |
Radio System |
|
|
System: Electret Ion Chamber
Surfaces contaminated with alpha activity
Radiation detected : Alpha
Operation
This system is a passive integrating detector system for measurement of alpha-emitting contaminants on surfaces... more |
| ALPHA (NORM) CONTAMINATION IN PIPES, TOOLS AND OBJECTS |
Radio System |
|
|
System: Ion Transfer Electret Ion Chamber
Lab/Field: Field (In situ measurement )
Radiation detected : NORM ( naturally occurring radioactive materials) and other alpha emitting isotopes such as plutonium inside pipes, on contaminated tools... more |
| WPC-9550 Automatic Low Background System |
Radio System |
|
|
0.05 Alpha CPM Background
0.45 Beta CPM Background
Automatic 50/100 Sample Changer
Ultra Thin Window
430 Pounds Installed
Gas-PRO Fail-Safe Counting
Window change in 4-5 minutes
No lead lifting required
... more |
| WPC-9450 Automatic 5 System |
Radio System |
|
|
0.15 CPM typical alpha background
2.5 CPM typical beta background
Automatic 50 Sample Changer
Sample size up to 5 inch diameter
Thin Window
Gas-PRO Fail-Safe Counting
Window change in 10-15 minutes
No rear access... more |
| Positron Lifetime Picosecond Timing System |
Radio System |
|
|
The existence of the positron, first predicted by Dirac, was experimentally identified in the 1930s. The positron is the antiparticle of the electron. A positron collision with an electron results in the annihilation of both particles and the emission... more |
| MPC-2000 & MPC-2000-PC Desktop Alpha/Beta Counter |
Radio System |
|
|
0.05 Alpha CPM Background
40-50 Beta CPM Background
Window or Windowless Operation
Ultra Thin Window
No drop through sample drawer
Single finger drawer operation
35 Pounds without optional shield
Loss free counting
... more |
| MDS Multi-detector Manual System |
Radio System |
|
|
0.05 Alpha CPM Background
0.45 Beta CPM Background
4 to 64 Detectors per system
Ultra Thin Window
Gas-PRO Fail-Safe Counting
Window change in 4-5 minutes
1 Drawer per Detector
No lead lifting or rear access required... more |
| FTA820A Octal Fast Timing Amplifier |
Amplifier |
|
|
For amplifying fast analog signals from photomultipliers, electron multipliers, photodiodes, microchannel plates, and silicon charged-particle detectors
£20 mV rms equivalent input noise
£1 ns rise time
Gain: 200
Output drives -5... more |
| CO4020 Quad 4-Input Logic Unit |
Radio System |
|
|
General-purpose logic module for AND, OR, Veto, Fan-Out, and Gating functions
Four independent channels
Overlap outputs and adjustable-width outputs
3-ns overlap resolution
TTL and fast negative NIM outputs
The ORTEC Model... more |
| Chemical Weapons Assay |
Radio System |
|
|
miniPINS Portable Isotopic Neutron-Spectroscopy Chemical Assay System
Second Generation Neutron-Based NDE System for Identification of Chemical Warfare Agents, Explosives, and Toxic Industrial Chemicals
Second Generation Non-Destructive Chemical... more |